Files
geant4/source/processes/electromagnetic/adjoint/include/G4AdjointPhotoElectricModel.hh
T
2021-06-25 16:12:29 +02:00

95 lines
4.4 KiB
C++

//
// ********************************************************************
// * License and Disclaimer *
// * *
// * The Geant4 software is copyright of the Copyright Holders of *
// * the Geant4 Collaboration. It is provided under the terms and *
// * conditions of the Geant4 Software License, included in the file *
// * LICENSE and available at http://cern.ch/geant4/license . These *
// * include a list of copyright holders. *
// * *
// * Neither the authors of this software system, nor their employing *
// * institutes,nor the agencies providing financial support for this *
// * work make any representation or warranty, express or implied, *
// * regarding this software system or assume any liability for its *
// * use. Please see the license in the file LICENSE and URL above *
// * for the full disclaimer and the limitation of liability. *
// * *
// * This code implementation is the result of the scientific and *
// * technical work of the GEANT4 collaboration. *
// * By using, copying, modifying or distributing the software (or *
// * any work based on the software) you agree to acknowledge its *
// * use in resulting scientific publications, and indicate your *
// * acceptance of all terms of the Geant4 Software license. *
// ********************************************************************
//
////////////////////////////////////////////////////////////////////////////////
// Class: G4AdjointPhotoElectricModel
// Author: L. Desorgher
// Organisation: SpaceIT GmbH
//
// Model for the adjoint photo electric process.
// Put a higher limit on the CS to avoid a high rate of Inverse Photo e-effect
// at low energy. The very high adjoint CS of the reverse photo electric
// reaction produce a high rate of reverse photo electric reaction in the inner
// side of a shielding for eaxmple, the correction of this occurrence by weight
// correction in the StepDoIt method is not statistically sufficient at small
// energy. The problem is partially solved by setting a higher CS limit and
// compensating it by an extra weight correction factor. However when coupling
// it with other reverse processes the reverse photo-electric is still the
// source of very occasional high weights that decrease the efficiency of the
// computation. A way to solve this problemn is still needed but is difficult
// to find as it happens in rare cases but does give a weight that is outside
// the normal distribution. (Very Tricky!)
//
////////////////////////////////////////////////////////////////////////////////
#ifndef G4AdjointPhotoElectricModel_h
#define G4AdjointPhotoElectricModel_h 1
#include "globals.hh"
#include "G4VEmAdjointModel.hh"
class G4AdjointPhotoElectricModel : public G4VEmAdjointModel
{
public:
G4AdjointPhotoElectricModel();
~G4AdjointPhotoElectricModel() override;
void SampleSecondaries(const G4Track& aTrack, G4bool isScatProjToProj,
G4ParticleChange* fParticleChange) override;
G4double AdjointCrossSection(const G4MaterialCutsCouple* aCouple,
G4double primEnergy,
G4bool isScatProjToProj) override;
G4double AdjointCrossSectionPerAtom(const G4Element* anElement,
G4double electronEnergy);
G4AdjointPhotoElectricModel(G4AdjointPhotoElectricModel&) = delete;
G4AdjointPhotoElectricModel& operator=(
const G4AdjointPhotoElectricModel& right) = delete;
protected:
void CorrectPostStepWeight(G4ParticleChange* fParticleChange,
G4double old_weight, G4double adjointPrimKinEnergy,
G4double projectileKinEnergy,
G4bool isScatProjToProj) override;
private:
void DefineCurrentMaterialAndElectronEnergy(
const G4MaterialCutsCouple* aCouple, G4double eEnergy);
G4double fShellProb[40][40];
G4double fXsec[40];
G4double fTotAdjointCS = 0.;
G4double fFactorCSBiasing = 1.;
G4double fPreStepAdjointCS = 0.;
G4double fPostStepAdjointCS = 0.;
G4double fCurrenteEnergy = 0.;
size_t fIndexElement = 0;
};
#endif