Files
geant4/examples/advanced/hadrontherapy/macro/ExternalSource.mac
T
2018-12-07 15:15:39 +01:00

144 lines
3.1 KiB
Plaintext
Executable File

# G.A.P.Cirrone
#
# Default macro file. It is called if no argument is provided at run
#
# i.e. simply typing $G4WORKDIR/bin/Linux-++/Hadrontherapy <no argument here!>
#
# This macro can be used for a proton beam in water. Both electrmagnetic and
# hadronic models are swiched on
#########################
# Set of the verboses
#
/control/verbose 1
/tracking/verbose 0
/run/verbose 1
/event/verbose 0
##########################
# Set of the physic models
#
/Physics/addPhysics QGSP_BIC_EMY
/run/numberOfThreads 4
##########################
# INFN-LNS transport beam line,
# normally used for interdisciplinary
# researches with carbon and
# and other ion beams is activated
# with the following command
#
/geometrySetup/selectGeometry Carbon
##########################
# Initialisation procedure
#
/run/initialize
##########################
# Visualisation
#
#/vis/open OGLI 600x600-0+0
# Disable auto refresh and quieten vis messages whilst scene and
# trajectories are established:
#/vis/viewer/set/autoRefresh false
#/vis/verbose errors
#/vis/drawVolume
#/vis/viewer/set/viewpointThetaPhi 30 140 deg
#/vis/viewer/zoom 1
#/vis/viewer/pan -10 0 cm
#/vis/scene/add/trajectories smooth
#/vis/scene/endOfEventAction accumulate
#/vis/viewer/set/autoRefresh true
#/vis/verbose warnings
##########################
# Set here the cut and the step max for the tracking.
# Suggested values of cut and step:
# Set cuts OUTSIDE the detector
/run/setCut 10 mm
# Set cuts ONLY inside the detector
#
/run/setCutForRegion DetectorLog 0.1 mm
/Step/waterPhantomStepMax 0.1 mm
##########################################################################################################
# PRIMARY PARTICLES
# the beam spot is centered at the origin and is
# of 1d gaussian shape with a 3mm central plateau
#
#---------------------------gps-----------------
/gps/pos/shape Circle
/gps/pos/centre -80. 0. 0. mm
/gps/pos/radius 0. mm
/gps/pos/sigma_r 2. mm
/gps/particle ion
/gps/ion 6 12 6
/gps/pos/type Beam
# the incident surface is in the y-z plane
/gps/pos/rot1 0 1 0
/gps/pos/rot2 0 0 1
# the beam is travelling along the x-axis without any angular dispersion (angular despersion set to 0.0)
#
/gps/ang/rot1 0 0 1
/gps/ang/rot2 0 1 0
/gps/ang/type beam1d
/gps/ang/sigma_r 0. deg
# the beam energy is in gaussian profile
#
/gps/ene/type Gauss
/gps/ene/mono 744 MeV
/gps/ene/sigma 0.740 MeV
# Voxelised detector
/changePhantom/size 40 40 40 cm
/changePhantom/position 20 0 0 cm
/changeDetector/size 4 4 4 cm
/changeDetector/voxelSize .1 40 40 mm
# Put the detector in the lower left corner of the phantom
/changeDetector/displacement 0 18 18 cm
/changePhantom/update
/changeTheSource/VirtualLayer true
/changeTheSource/VirtualLayerPosition -4 0 0 cm
/primaryParticleData/NewSource true
/primaryParticleData/calculatedPhaseSpaceFileIN Layer_TuttaLinea.txt
#########################
# Display the event number
# during the run
#
/run/printProgress 1000
# Compute Dose and Fluence for secondary
#/analysis/secondary true
#########################
# Start of the run
#
#########################
/run/beamOn 1