$Id: README,v 1.1 1999/10/12 12:23:17 maire Exp $
-------------------------------------------------------------------
=========================================================
Geant4 - an Object-Oriented Toolkit for Simulation in HEP
=========================================================
TestEm5
-------
1- GEOMETRY DEFINITION
The "absorber" is a box made of a given material.
Three parameters define the absorber :
- the material of the absorber,
- the thickness of an absorber,
- the transverse size of the absorber (the input face is a square).
The volume "World" contains the "absorber".
In this test the parameters of the "World" can be changed , too.
In addition a transverse uniform magnetic field can be applied.
The default geometry is constructed in DetectorConstruction class,
but all the parameters can be changed via
the commands defined in the DetectorMessenger class.
2- AN EVENT : THE PRIMARY GENERATOR
The primary kinematic consists of a single particle which hits the
absorber perpendicular to the input face. The type of the particle
and its energy are set in the PrimaryGeneratorAction class, and can
be changed via the G4 build-in commands of ParticleGun class (see
the macros provided with this example).
A RUN is a set of events.
3- DETECTOR RESPONSE
A HIT is a record, event per event , of all the
informations needed to simulate and analyse the detector response.
In this example a CalorHit is defined as a set of 2 informations:
- the total energy deposit in the absorber,
- the total tracklength of all charged particles in the absorber,
Therefore the absorber is declared
'sensitive detector' (SD), which means they can contribute to the hit.
At the end of a run, from the histogram(s), one can study
different physics quantities such as :
- angle distribution,
- energy deposit,
- transmission/backscattering,
- ...
The test contains 10 built-in histograms, which can be activated by
interactive commands (see the macros runxx.mac for details).
The histograms/plots are in printed form in the corresponding
resultxx (for GEANT4) and outxx (for GEANT3) files, and they are
saved as geant4.plotxx and geant3.plotxx histogram files, too.
The histogram files can be viewed using PAW e.g with the commands
paw> h/file 1 geant4.plot01
paw> option stat
paw> h/pl 1
4- PHYSICS DEMO
The particle's type and the physic processes which will be available
in this example are set in PhysicsList class.
The messenger classes introduce interactive commands . Using these
commands the geometry of the detector, the data of the primary
particle, the limits of the histograms , etc. can be changed.
5- HOW TO START ?
- compile and link to generate an executable
% cd TestEm5
% gmake
- execute TestEm5 in 'batch' mode from macro files e.g.
% $(G4INSTALL)/bin/$(G4SYSTEM)/TestEm5 run01.mac
- execute TestEm5 in 'interactive' mode with visualization e.g.
% $(G4INSTALL)/bin/$(G4SYSTEM)/TestEm5
....
Idle> type your commands
....
6- GEANT4/GEANT3/exp.data comparison
A GEANT4/GEANT3/exp. data comparison is given here for a few cases.
The GEANT4 results can be found in the results/ directory, the resultxx
output was obtained with the runxx.mac macro.
The relevant part of the GEANT3 code is in the geant3/ directory
together with the runxx.dat input files. The outputs of the GEANT3 runs
geant3/results subdirectory.
In order to make an executable of GEANT3 the gmakeB command should be
used in the geant3/ subdirectory.To run this executable with a given
input file the input file name should be given when it is being asked
by the program.(see geant3/README)
The expdata/ directory contains some information
on the experimental data.
List of the built-in histograms
-------------------------------
1. number of (tracking) steps/event
2. energy deposit distribution in the absorber (in MeV)
3. angle distribution of the primary particle at the exit
of the absorber (deg)
4. distribution of the lateral displacement at exit(mm)
5. kinetic energy of the transmitted primaries (MeV)
6. angle distribution of the backscattered primaries (deg)
7. kinetic energy of the backscattered primary particles (MeV)
8. kinetic energy of the charged secondary particles (MeV)
9. z distribution of the secondary charged vertices (mm)
10. kinetic energy of the photons escaping the absorber (MeV)