$Id: README,v 1.5 2008/06/11 11:56:16 sincerti Exp $
-------------------------------------------------------------------
=========================================================
Geant4 - Microdosimetry example
=========================================================
README file
----------------------
CORRESPONDING AUTHOR
S. Incerti (a, *) et al.
a. Centre d'Etudes Nucleaires de Bordeaux-Gradignan
(CENBG), IN2P3 / CNRS / Bordeaux 1 University, 33175 Gradignan, France
* e-mail:incerti@cenbg.in2p3.fr
Last modified by S. Incerti, 27/02/2007
---->0. INTRODUCTION.
The microdosimetry example simulates the track of a 10 keV Helium+ (positive
charge is +e) particle in liquid water using only G4DNA processes.
---->1. GEOMETRY SET-UP.
The geometry is a 1 mm side cube of liquid water.
---->2. SET-UP
- a standard Geant4 example GNUmakefile is provided
setup with:
compiler = gcc-3.4.6
G4SYSTEM = linux-g++
The following section gives the necessary environment variables.
------->>2.1 ENVIRONMENT VARIABLES
All variables are defined with their default value.
- G4SYSTEM = Linux-g++
- G4INSTALL points to the installation directory of GEANT4;
- G4LIB point to the compiled libraries of GEANT4;
- G4WORKDIR points to the work directory;
- CLHEP_BASE_DIR points to the installation directory of CHLEP;
- G4LEDATA points to the low energy electromagnetic libraries;
- LD_LIBRARY_PATH = $CLHEP_BASE_DIR/lib
- G4LEVELGAMMADATA points to the photoevaporation library;
- NeutronHPCrossSections points to the neutron data files;
- G4RADIOACTIVEDATA points to the libraries for radio-active decay
hadronic processes;
However, the $G4LEVELGAMMADATA, $NeutronHPCrossSections and $G4RADIOACTIVEDATA
variables do not need to be defined for this example.
Once these variables have been set, simply type gmake to compile the
Microdosimetry example.
------->>2.2 VISUALIZATION
Visualization is not activated by default.
---->3. HOW TO RUN THE EXAMPLE
In interactive mode, run:
> $G4WORDIR/bin/$G4SYSTEM/Microdosimetry
The macro microdosimetry.mac is executed by default.
To get visualization, make sure to uncomment the /vis/... lines in the macro.
---->4. PHYSICS
This example shows how to use the Geant4 DNA processes AND how to affect them a
name.
Look at the PhyscisList.cc file.
Note that the G4CrossSectionElasticScreenedRutherford.cc is put in the src
directory with an increased (10 eV instead of 7 eV) lower limit of the model energy range to
avoid an energy region where electrons do not lose any energy and may undergo
elastic scattering without limit.
Same remark for the G4CrossSectionExcitationEmfietzoglou.cc file whre the lower
limit has been set to 10 eV instead of 7.4 eV.
---->5. SIMULATION OUTPUT AND RESULT ANALYZIS
This example does not need any external analysis package.
The output results consists in a track.txt file, containing at each line :
- the type of particle for the current step
- the type of process for the current step
- the track position of the current step (in nanometers)
This file can be easily analyzed using for example the provided ROOT macro
file plot.C; to do so :
* be sure to have ROOT installed on your machine
* be sure to be in the microdosimetry directory
* launch ROOT by typing root
* under your ROOT session, type in : .X plot.C to execute the macro file
The naming scheme on the displayed ROOT plots is as follows (see SteppingAction.cc):
-particles:
e- : 1
proton : 2
hydrogen : 3
alpha : 4
alpha+ : 5
helium : 6
-processes:
ElasticBrennerZaider : 11
ElasticScreenedRutherford : 12
ExcitationBorn : 13
ExcitationEmfietzoglou : 14
ExcitationMillerGreen : 15
IonisationBorn : 16
IonisationRudd : 17
ChargeDecrease : 18
ChargeIncrease : 19
---------------------------------------------------------------------------
Should you have any enquiry, please do not hesitate to contact:
incerti@cenbg.in2p3.fr