Files
geant4/examples/advanced/doiPET/include/doiPETGlobalParameters.hh
T
2018-12-07 15:15:39 +01:00

72 lines
3.3 KiB
C++

//
// ********************************************************************
// * License and Disclaimer *
// * *
// * The Geant4 software is copyright of the Copyright Holders of *
// * the Geant4 Collaboration. It is provided under the terms and *
// * conditions of the Geant4 Software License, included in the file *
// * LICENSE and available at http://cern.ch/geant4/license . These *
// * include a list of copyright holders. *
// * *
// * Neither the authors of this software system, nor their employing *
// * institutes,nor the agencies providing financial support for this *
// * work make any representation or warranty, express or implied, *
// * regarding this software system or assume any liability for its *
// * use. Please see the license in the file LICENSE and URL above *
// * for the full disclaimer and the limitation of liability. *
// * *
// * This code implementation is the result of the scientific and *
// * technical work of the GEANT4 collaboration. *
// * By using, copying, modifying or distributing the software (or *
// * any work based on the software) you agree to acknowledge its *
// * use in resulting scientific publications, and indicate your *
// * acceptance of all terms of the Geant4 Software license. *
// ********************************************************************
//GEANT4 - Depth-of-Interaction enabled Positron emission tomography (PET) advanced example
//Authors and contributors
// Author list to be updated, with names of co-authors and contributors from National Institute of Radiological Sciences (NIRS)
// Abdella M. Ahmed (1, 2), Andrew Chacon (1, 2), Harley Rutherford (1, 2),
// Hideaki Tashima (3), Go Akamatsu (3), Akram Mohammadi (3), Eiji Yoshida (3), Taiga Yamaya (3)
// Susanna Guatelli (2), and Mitra Safavi-Naeini (1, 2)
// (1) Australian Nuclear Science and Technology Organisation, Australia
// (2) University of Wollongong, Australia
// (3) National Institute of Radiological Sciences, Japan
//The header file consists of specification if the scanner geometry
//Number of crystals (scintillators) in the DOI (x), tangential (y) and axial (z) direction.
#define numberOfCrystal_DOI 4
#define numberOfCrystal_tangential 16
#define numberOfCrystal_axial 16
//size of the crystals in the DOI (x), tangential (y) and axial (z) direction.
#define sizeOfCrystal_DOI 7.5*mm
#define sizeOfCrystal_tangential 2.8*mm
#define sizeOfCrystal_axial 2.8*mm
//Inter crystal gap between crystals.
#define crystalGap_DOI 0.0*mm
#define crystalGap_tangential 0.08*mm
#define crystalGap_axial 0.08*mm
//Define Aluminum thickness cover for the detector
#define AluminumCoverThickness 0.3 * mm
//Number of PET detectors per ring
#define numberOfDetector_perRing 40
//Number of rings in the PET system
#define numberOfRings 4
//Radius of the PET system. Note that the radius is defined between to opposing sensitive detectors (It does not include detector block cover).
#define scannerRadius 330 * mm
//Gap between two adjacent rings. There are three gaps in four ring PET system
#define ringGap 10.4 * mm