Files
geant4/examples/advanced/brachytherapy/IodiumSourceMacro.out
T
2016-06-09 10:41:53 +02:00

117 lines
4.3 KiB
Plaintext

**********************************************
Geant4 version $Name: geant4-06-00 $
(19-May-2003)
Copyright : Geant4 Collaboration
**********************************************
Visualization Manager instantiating...
Visualization Manager initialising...
Registering graphics systems...
User Environment
Using AIDA 3.0 analysis
Bremsstrahlung Angular Generator is Modified Tsai
Universal distribution suggested by L. Urban (Geant3 manual (1993) Phys211)
Derived from Tsai distribution (Rev Mod Phys 49,421(1977))
BrachyPhysicsList::SetCuts:CutLength : 100 mum
/run/verbose 0
/event/verbose 0
/source/switch Iodium
Now Detector is Iodium
/run/energy Iodium
/run/initialize
/run/beamOn 100
msc: Tables of transport mean free paths.
New model of MSC , computes the lateral
displacement of the particle , too.
PhysicsTables from 100 eV to 100 TeV in 100 bins.
G4AugerData for Element no. 6 are loaded
G4AugerData for Element no. 7 are loaded
G4AugerData for Element no. 8 are loaded
G4AugerData for Element no. 11 are loaded
G4AugerData for Element no. 12 are loaded
G4AugerData for Element no. 13 are loaded
G4AugerData for Element no. 14 are loaded
G4AugerData for Element no. 15 are loaded
G4AugerData for Element no. 16 are loaded
G4AugerData for Element no. 17 are loaded
G4AugerData for Element no. 19 are loaded
G4AugerData for Element no. 20 are loaded
G4AugerData for Element no. 22 are loaded
G4AugerData for Element no. 24 are loaded
G4AugerData for Element no. 25 are loaded
G4AugerData for Element no. 26 are loaded
G4AugerData for Element no. 28 are loaded
G4AugerData for Element no. 30 are loaded
G4AugerData for Element no. 53 are loaded
G4AugerData for Element no. 74 are loaded
G4AugerData for Element no. 77 are loaded
G4AugerData for Element no. 79 are loaded
G4AugerData for Element no. 82 are loaded
AugerTransitionTable complete
LowEnergyIoni: Total cross sections from EEDL database.
Gamma energy sampled from a parametrised formula.
Implementation of the continuous dE/dx part.
At present it can be used for electrons in the energy range [250eV,100GeV].
The process must work with G4LowEnergyBremsstrahlung.
LowEnBrem: Total cross sections from EEDL database.
Gamma energy sampled from a parameterised formula.
Implementation of the continuous dE/dx part.
At present it can be used for electrons in the energy range [250eV,100GeV].
The process must work with G4LowEnergyIonisation.
annihil: Total cross section from Heilter formula(annihilation into 2 photons).
gamma energies sampled according Heitler
PhysicsTables from 10 keV to 10 TeV in 100 bins.
========= Table of registered couples ==============================
Index : 0 used in the geometry : Yes recalculation needed : No
Material : Air
Range cuts : gamma 100 mum e- 100 mum e+ 100 mum
Energy thresholds : gamma 990 eV e- 990 eV e+ 990 eV
Region(s) which use this couple :
DefaultRegionForTheWorld
Index : 1 used in the geometry : Yes recalculation needed : No
Material : tissue
Range cuts : gamma 100 mum e- 100 mum e+ 100 mum
Energy thresholds : gamma 1.06471 keV e- 84.2696 keV e+ 83.2385 keV
Region(s) which use this couple :
DefaultRegionForTheWorld
Index : 2 used in the geometry : Yes recalculation needed : No
Material : titanium
Range cuts : gamma 100 mum e- 100 mum e+ 100 mum
Energy thresholds : gamma 4.09208 keV e- 165.852 keV e+ 161.818 keV
Region(s) which use this couple :
DefaultRegionForTheWorld
Index : 3 used in the geometry : Yes recalculation needed : No
Material : Iodium
Range cuts : gamma 100 mum e- 100 mum e+ 100 mum
Energy thresholds : gamma 9.58329 keV e- 152.158 keV e+ 148.458 keV
Region(s) which use this couple :
DefaultRegionForTheWorld
Index : 4 used in the geometry : Yes recalculation needed : No
Material : gold
Range cuts : gamma 100 mum e- 100 mum e+ 100 mum
Energy thresholds : gamma 40.2739 keV e- 347.138 keV e+ 334.551 keV
Region(s) which use this couple :
DefaultRegionForTheWorld
====================================================================
The Ntuple is non-zero
number of event = 100
Graphics systems deleted.
Visualization Manager deleting...