72 lines
3.3 KiB
C++
72 lines
3.3 KiB
C++
//
|
|
// ********************************************************************
|
|
// * License and Disclaimer *
|
|
// * *
|
|
// * The Geant4 software is copyright of the Copyright Holders of *
|
|
// * the Geant4 Collaboration. It is provided under the terms and *
|
|
// * conditions of the Geant4 Software License, included in the file *
|
|
// * LICENSE and available at http://cern.ch/geant4/license . These *
|
|
// * include a list of copyright holders. *
|
|
// * *
|
|
// * Neither the authors of this software system, nor their employing *
|
|
// * institutes,nor the agencies providing financial support for this *
|
|
// * work make any representation or warranty, express or implied, *
|
|
// * regarding this software system or assume any liability for its *
|
|
// * use. Please see the license in the file LICENSE and URL above *
|
|
// * for the full disclaimer and the limitation of liability. *
|
|
// * *
|
|
// * This code implementation is the result of the scientific and *
|
|
// * technical work of the GEANT4 collaboration. *
|
|
// * By using, copying, modifying or distributing the software (or *
|
|
// * any work based on the software) you agree to acknowledge its *
|
|
// * use in resulting scientific publications, and indicate your *
|
|
// * acceptance of all terms of the Geant4 Software license. *
|
|
// ********************************************************************
|
|
|
|
//GEANT4 - Depth-of-Interaction enabled Positron emission tomography (PET) advanced example
|
|
|
|
//Authors and contributors
|
|
|
|
// Author list to be updated, with names of co-authors and contributors from National Institute of Radiological Sciences (NIRS)
|
|
|
|
// Abdella M. Ahmed (1, 2), Andrew Chacon (1, 2), Harley Rutherford (1, 2),
|
|
// Hideaki Tashima (3), Go Akamatsu (3), Akram Mohammadi (3), Eiji Yoshida (3), Taiga Yamaya (3)
|
|
// Susanna Guatelli (2), and Mitra Safavi-Naeini (1, 2)
|
|
|
|
// (1) Australian Nuclear Science and Technology Organisation, Australia
|
|
// (2) University of Wollongong, Australia
|
|
// (3) National Institute of Radiological Sciences, Japan
|
|
|
|
//The header file consists of specification if the scanner geometry
|
|
|
|
//Number of crystals (scintillators) in the DOI (x), tangential (y) and axial (z) direction.
|
|
#define numberOfCrystal_DOI 4
|
|
#define numberOfCrystal_tangential 16
|
|
#define numberOfCrystal_axial 16
|
|
|
|
//size of the crystals in the DOI (x), tangential (y) and axial (z) direction.
|
|
#define sizeOfCrystal_DOI 7.5*mm
|
|
#define sizeOfCrystal_tangential 2.8*mm
|
|
#define sizeOfCrystal_axial 2.8*mm
|
|
|
|
//Inter crystal gap between crystals.
|
|
#define crystalGap_DOI 0.0*mm
|
|
#define crystalGap_tangential 0.08*mm
|
|
#define crystalGap_axial 0.08*mm
|
|
|
|
|
|
|
|
//Define Aluminum thickness cover for the detector
|
|
#define AluminumCoverThickness 0.3 * mm
|
|
|
|
//Number of PET detectors per ring
|
|
#define numberOfDetector_perRing 40
|
|
|
|
//Number of rings in the PET system
|
|
#define numberOfRings 4
|
|
|
|
//Radius of the PET system. Note that the radius is defined between to opposing sensitive detectors (It does not include detector block cover).
|
|
#define scannerRadius 330 * mm
|
|
|
|
//Gap between two adjacent rings. There are three gaps in four ring PET system
|
|
#define ringGap 10.4 * mm |