G4StoppingPhysics
|
|
-----------------
|
|
It uses Bertini/Precompound (i.e. Bertini followed by the official
|
|
Precompound/deexcitation of Geant4, not the internal one of Bertini)
|
|
for nuclear capture of: pi-, K-, Sigma-, Xi- and Omega-.
|
|
It uses Fritiof/Precompound model for nuclear capture of: anti_proton,
|
|
anti_neutron, anti_Lambda, anti_Sigma0, anti_Sigma+, anti_Xi0,
|
|
anti_deuteron, anti_triton, anti_He3, and anti_alpha.
|
|
For mu-, Bertini model is used for nuclear capture, together with
|
|
default element selector, EM cascade sampling and bound decay sampling.
|
|
|
|
G4StoppingPhysicsFritiofWithBinaryCascade
|
|
-----------------------------------------
|
|
The same as G4StoppingPhysics, except that for anti-proton and anti-neutron
|
|
annihilation at rest it uses Fritiof coupled with Binary Cascade.
|
|
|
|
G4StoppingPhysicsWithINCLXX
|
|
---------------------------
|
|
The same as G4StoppingPhysics, except that for anti-proton annihilation
|
|
at rest it uses the INCLXX model.
|