# # Macro file for "TestEm16.cc" # (can be run in batch, without graphic) # # /control/verbose 2 /run/numberOfThreads 2 /control/cout/ignoreThreadsExcept 0 /run/verbose 1 # /testem/det/setMat Vacuum # /run/initialize # # inactivate other processes to make SynchrotronRadiation more visible /process/inactivate msc /process/inactivate eIoni /process/inactivate eBrem /process/inactivate annihil /process/inactivate phot /process/inactivate compt /process/inactivate conv /process/inactivate Rayl # /globalField/setValue 0 0 1 tesla # /gun/particle e- /gun/energy 9.9994890009 GeV # # expected results is: # Emean = 20.48 keV # E_rms = 37.18 keV # /run/beamOn 100