# Example eFLASH_radiotherapy History See `CONTRIBUTING.rst` for details of **required** info/format for each entry, which **must** added in reverse chronological order (newest at the top). It must **not** be used as a substitute for writing good git commit messages! ## 2025-11-04 G. Milluzzo (eFLASH_radiotherapy-V11-03-00) - Added the new class FlashMinibeamTemplate implementing the geometry of collimatiors for minibeam production, including the different geometrical configurations (grid and planar) - Modified FlashDetectorConstruction accordigly - Added a macro file for minibeam production ## 2024-11-09 G. Milluzzo (eFLASH_radiotherapy-V11-02-02) - Added a new geometry in DetectorConstruction:added an array of multiple small size silicon carbide detectors within the water phantom for dose distribution computation - Added the sensitive detector class for the silicon carbide array - Updated the macro files ## 2024-08-12 I. Hrivnacova (eFLASH_radiotherapy-V11-02-01) - Removed unused includes of G4Accumulable[Manager].hh from FlashRunAction ## 2024-01-10 G. Milluzzo (eFLASH_radiotherapy-V11-02-00) - Added the FlashPhysicsListMessenger class to change the physics lists by macro commands (opt3,opt4,penelope and livermore) ## 2023-11-15 I. Hrivnacova (eFLASH_radiotherapy-V11-01-02) - Updated vis.mac: - Changed "/vis/open XYZ [600x600-0+0]" to "/vis/open" to allow run-time choices and simplified comments. ## 2023-11-10 A. Ribon (eFLASH_radiotherapy-V11-01-01) - In all macro files, introduced the UI command '/process/had/rdm/thresholdForVeryLongDecayTime 1.0e+60 year' to allow all radioactive decays (including the very long ones). This is necessary since G4 11.2, being 1 year the default time threshold above which the decays are ignored. ## 2023-06-19 G. Milluzzo (eFLASH_radiotherapy-V11-01-00) - Removed visualization in batch mode ## 2022-11-18 F. Romano (eFLASH_radiotherapy-V11-00-00) - Added the new advanced example eFLASH_radiotherapy