Import Geant4 11.2.0 source tree
This commit is contained in:
@@ -11,7 +11,7 @@ Environment variable "G4FORCE_RUN_MANAGER_TYPE" enabled with value == Serial. Fo
|
||||
|
||||
|
||||
**************************************************************
|
||||
Geant4 version Name: geant4-11-01-ref-06 (30-June-2023)
|
||||
Geant4 version Name: geant4-11-02-ref-00 (8-December-2023)
|
||||
Copyright : Geant4 Collaboration
|
||||
References : NIM A 506 (2003), 250-303
|
||||
: IEEE-TNS 53 (2006), 270-278
|
||||
@@ -46,6 +46,10 @@ Registered graphics systems are:
|
||||
TOOLSSG_XT_ZB (TSG_XT_ZB, TSGXtZB)
|
||||
TOOLSSG_QT_GLES (TSG_QT_GLES, TSGQt, TSG)
|
||||
TOOLSSG_QT_ZB (TSG_QT_ZB, TSGQtZB)
|
||||
Default graphics system is: TSG_OFFSCREEN (based on batch session).
|
||||
Default window size hint is: 600x600-0+0 (based on G4VisManager initialisation).
|
||||
Note: Parameters specified on the command line will override these defaults.
|
||||
Use "vis/open" without parameters to get these defaults.
|
||||
|
||||
Registering model factories...
|
||||
|
||||
@@ -455,9 +459,15 @@ Auger electron emission enabled 1
|
||||
Check EM cuts disabled for atomic de-excitation 1
|
||||
Use Bearden atomic level energies 0
|
||||
Use ANSTO fluorescence model 0
|
||||
Threshold for very long decay time at rest 3.171e+10 y
|
||||
Threshold for very long decay time at rest 1 y
|
||||
======================================================================
|
||||
|
||||
====================================================================
|
||||
HADRONIC PROCESSES SUMMARY (verbose level 1)
|
||||
-------------------------------------------------------------------------
|
||||
Hadronic Processes for GenericIon
|
||||
Process: Radioactivation
|
||||
|
||||
msc: for alpha SubType= 10
|
||||
===== EM models for the G4Region DefaultRegionForTheWorld ======
|
||||
UrbanMsc : Emin= 0 eV Emax= 100 TeV
|
||||
@@ -694,23 +704,6 @@ CoulombScat: for pi- XStype:1 SubType=1 BuildTable=1
|
||||
ThetaMin(p) < Theta(degree) < 180, pLimit(GeV^1)= 0.139531
|
||||
===== EM models for the G4Region DefaultRegionForTheWorld ======
|
||||
eCoulombScattering : Emin= 0 eV Emax= 100 TeV
|
||||
======================================================================
|
||||
====== Radioactive Decay Physics Parameters =======
|
||||
======================================================================
|
||||
min MeanLife (from G4NuclideTable) 1 ns
|
||||
Max life time (from G4DeexPrecoParameters) 1000 ps
|
||||
Internal e- conversion flag 1
|
||||
Stored internal conversion coefficients 1
|
||||
Enabled atomic relaxation mode 1
|
||||
Enable correlated gamma emission 0
|
||||
Max 2J for sampling of angular correlations 10
|
||||
Atomic de-excitation enabled 1
|
||||
Auger electron emission enabled 1
|
||||
Check EM cuts disabled for atomic de-excitation 1
|
||||
Use Bearden atomic level energies 0
|
||||
Use ANSTO fluorescence model 0
|
||||
Threshold for very long decay time at rest 3.171e+10 y
|
||||
======================================================================
|
||||
G4VisManager: Using G4TrajectoryDrawByCharge as fallback trajectory model.
|
||||
See commands in /vis/modeling/trajectories/ for other options.
|
||||
### Run 0 starts.
|
||||
@@ -740,8 +733,8 @@ Setting was ignored.
|
||||
--> Event 9000 starts.
|
||||
|
||||
--------------------End of Global Run-----------------------
|
||||
The run was 10000 events Nb of 'good' e+ annihilations: 1275
|
||||
Total dose in patient : 308.987 picoGy
|
||||
The run was 10000 events Nb of 'good' e+ annihilations: 1259
|
||||
Total dose in patient : 307.488 picoGy
|
||||
------------------------------------------------------------
|
||||
|
||||
... write file : scoring.root - done
|
||||
|
||||
Reference in New Issue