Import Geant4 11.1.1 source tree
This commit is contained in:
@@ -11,7 +11,7 @@ Environment variable "G4FORCE_RUN_MANAGER_TYPE" enabled with value == Serial. Fo
|
||||
|
||||
|
||||
**************************************************************
|
||||
Geant4 version Name: geant4-11-01-ref-00 (9-December-2022)
|
||||
Geant4 version Name: geant4-11-01-patch-01 (10-February-2023)
|
||||
Copyright : Geant4 Collaboration
|
||||
References : NIM A 506 (2003), 250-303
|
||||
: IEEE-TNS 53 (2006), 270-278
|
||||
@@ -693,6 +693,23 @@ CoulombScat: for pi- XStype:1 SubType=1 BuildTable=1
|
||||
ThetaMin(p) < Theta(degree) < 180 pLimit(GeV^1)= 0.139531
|
||||
===== EM models for the G4Region DefaultRegionForTheWorld ======
|
||||
eCoulombScattering : Emin= 0 eV Emax= 100 TeV
|
||||
======================================================================
|
||||
====== Radioactive Decay Physics Parameters =======
|
||||
======================================================================
|
||||
min MeanLife (from G4NuclideTable) 1 ns
|
||||
Max life time (from G4DeexPrecoParameters) 1000 ps
|
||||
Internal e- conversion flag 1
|
||||
Stored internal conversion coefficients 1
|
||||
Enabled atomic relaxation mode 1
|
||||
Enable correlated gamma emission 0
|
||||
Max 2J for sampling of angular correlations 10
|
||||
Atomic de-excitation enabled 1
|
||||
Auger electron emission enabled 1
|
||||
Check EM cuts disabled for atomic de-excitation 1
|
||||
Use Bearden atomic level energies 0
|
||||
Use ANSTO fluorescence model 0
|
||||
Threshold for very long decay time at rest 3.171e+10 y
|
||||
======================================================================
|
||||
G4VisManager: Using G4TrajectoryDrawByCharge as fallback trajectory model.
|
||||
See commands in /vis/modeling/trajectories/ for other options.
|
||||
### Run 0 starts.
|
||||
|
||||
@@ -11,7 +11,7 @@ Environment variable "G4FORCE_RUN_MANAGER_TYPE" enabled with value == Serial. Fo
|
||||
|
||||
|
||||
**************************************************************
|
||||
Geant4 version Name: geant4-11-01-ref-00 (9-December-2022)
|
||||
Geant4 version Name: geant4-11-01-patch-01 (10-February-2023)
|
||||
Copyright : Geant4 Collaboration
|
||||
References : NIM A 506 (2003), 250-303
|
||||
: IEEE-TNS 53 (2006), 270-278
|
||||
@@ -693,6 +693,23 @@ CoulombScat: for pi- XStype:1 SubType=1 BuildTable=1
|
||||
ThetaMin(p) < Theta(degree) < 180 pLimit(GeV^1)= 0.139531
|
||||
===== EM models for the G4Region DefaultRegionForTheWorld ======
|
||||
eCoulombScattering : Emin= 0 eV Emax= 100 TeV
|
||||
======================================================================
|
||||
====== Radioactive Decay Physics Parameters =======
|
||||
======================================================================
|
||||
min MeanLife (from G4NuclideTable) 1 ns
|
||||
Max life time (from G4DeexPrecoParameters) 1000 ps
|
||||
Internal e- conversion flag 1
|
||||
Stored internal conversion coefficients 1
|
||||
Enabled atomic relaxation mode 1
|
||||
Enable correlated gamma emission 0
|
||||
Max 2J for sampling of angular correlations 10
|
||||
Atomic de-excitation enabled 1
|
||||
Auger electron emission enabled 1
|
||||
Check EM cuts disabled for atomic de-excitation 1
|
||||
Use Bearden atomic level energies 0
|
||||
Use ANSTO fluorescence model 0
|
||||
Threshold for very long decay time at rest 3.171e+10 y
|
||||
======================================================================
|
||||
G4VisManager: Using G4TrajectoryDrawByCharge as fallback trajectory model.
|
||||
See commands in /vis/modeling/trajectories/ for other options.
|
||||
### Run 0 starts.
|
||||
|
||||
Reference in New Issue
Block a user